Fix Synology RS815+ Red Light Alert: Resistor Solution for Intel Atom Processors

Find AI Tools
No difficulty
No complicated process
Find ai tools

Fix Synology RS815+ Red Light Alert: Resistor Solution for Intel Atom Processors

Table of Contents

  1. Introduction
  2. Issue with Synology Rock Station
  3. Solution: Adding a Resistor
  4. Steps to Add a Resistor
  5. Soldering the Resistor
  6. Checking the Soldering
  7. Putting the NAS Server Back
  8. Powering On the NAS Server
  9. Verifying the NAS Server
  10. Conclusion

Issue with Synology Rock Station

In this article, we will discuss how to resolve a common issue with the Synology Rock Station, specifically the RS815 Plus model. Many users have reported facing problems after updating their Synology devices, resulting in a red light flashing and amber indicators for the hard drives. This issue is likely caused by a bug introduced in the update, which affects models with Atom processors. To address this, we will guide you through the process of adding a resistor to regulate the voltage and fix the bug.

Introduction

The Synology Rock Station RS815 Plus has been a reliable device for many users. However, after a recent update, some users have encountered a red light flashing and amber indicators for their hard drives. This issue can be frustrating, as it prevents the NAS server from functioning properly. Fortunately, there is a solution that involves adding a resistor to regulate the voltage and fix the bug caused by the update.

Issue with Synology Rock Station

The issue with the Synology Rock Station RS815 Plus arises when users update their devices. After the update, a red light starts flashing, indicating an error, and the hard drive indicators turn amber. This problem is not uncommon, and many users have reported facing it. It is believed that Synology introduced a bug in the update specifically targeting models with Atom processors, such as the RS815 Plus. As a result, many consumers have stopped using this product and opted to buy newer models.

Solution: Adding a Resistor

To resolve the issue with the Synology Rock Station, we will add a resistor to regulate the voltage going to the processor. This simple solution has been proven to fix the bug caused by the update and restore the functionality of the NAS server. By adding the resistor, we ensure that the current voltage supplied to the processor is precise, eliminating any potential errors or malfunctions.

Steps to Add a Resistor

To resolve the issue with the Synology Rock Station RS815 Plus, follow these steps to add a resistor:

  1. Remove the board panel on your Synology RS815 Plus to access the boards.
  2. Locate the RAM slots on the board, as we will need to place the resistor nearby.
  3. Obtain a resistor with a value of 100 ohms from a hardware or electronic store.
  4. Position the resistor on the first hole of the right side and the third hole of the Second row on the board.
  5. Ensure that the gold side of the resistor is facing up and the brown side is on the left.
  6. Prepare your soldering iron to solder the resistor onto the board securely.

Soldering the Resistor

Once you have positioned the resistor correctly, it's time to solder it onto the board. Follow these steps to ensure a proper soldering process:

  1. Double-check the placement of the resistor using a voltmeter to ensure it is positioned correctly.
  2. Proceed to solder the resistor onto the board, ensuring a secure connection.
  3. Once the soldering is complete, cut off any excess wiring or protruding components.
  4. Take Care not to damage any other components while cutting off the excess wiring.

Checking the Soldering

It is essential to verify the quality of the soldering to ensure that the resistor is correctly attached to the board. Follow these steps to confirm the soldering:

  1. Use a voltmeter to check the continuity and resistance on the soldered connection.
  2. If the voltmeter readings indicate a proper connection, proceed to the next step.
  3. If the voltmeter readings are abnormal or show a weak connection, re-solder the resistor.

Putting the NAS Server Back

After confirming the successful soldering of the resistor, it's time to put the NAS server back together. Follow these steps:

  1. Carefully place the board back into the NAS server, taking care not to damage any components.
  2. Ensure that all connections are secure and properly reassembled.
  3. Double-check that all cables and connectors are in their correct positions.

Powering On the NAS Server

Now that the NAS server is reassembled, it's time to power it on and test if the issue has been resolved. Follow these steps:

  1. Connect the power cable to the NAS server and plug it into a power source.
  2. Turn on the power switch or press the power button on the NAS server.
  3. Observe the status indicator lights to see if the red alert status has been resolved.
  4. Wait for the NAS server to boot up and load all the configuration settings.

Verifying the NAS Server

To ensure that the NAS server is functioning properly after adding the resistor, you can use the Synology Assistant software to check its status. Follow these steps:

  1. Run the Synology Assistant software on your computer.
  2. Check if the NAS server is detected and displayed in the Synology Assistant.
  3. Access the NAS server's graphical user interface (GUI) using the provided IP address.
  4. Verify that all settings and configurations are intact and the NAS server is fully functional.

Conclusion

By following the steps outlined in this article, you should be able to resolve the issue with the Synology Rock Station RS815 Plus. Adding a resistor to regulate the voltage is a simple yet effective solution to fix the bug caused by the update. Now, you can enjoy the full functionality of your NAS server without any issues. Remember, if you encounter any other problems or have further questions, don't hesitate to Seek assistance from a professional or consult the Synology support website for more information.

Highlights:

  • Issue: Red light flashing and amber indicators after Synology update
  • Solution: Adding a resistor to regulate voltage
  • Steps to add resistor and solder it securely
  • Checking soldering quality and continuity
  • Reassembling and powering on the NAS server
  • Verifying functionality using Synology Assistant

FAQ

Q: Can I use any resistor value other than 100 ohms? A: It is recommended to use a resistor with a value of 100 ohms, as it has been proven to fix the issue. Using a different resistor value might not provide the same results.

Q: What should I do if the NAS server does not power on after adding the resistor? A: If the NAS server does not power on or shows any abnormal behavior after adding the resistor, double-check the connections and soldering. If the issue persists, seek assistance from a professional or contact Synology support.

Q: Will adding the resistor void the warranty of my Synology Rock Station RS815 Plus? A: Adding a resistor to fix the issue should not void the warranty, as it is a recommended solution provided by the community. However, it is always advisable to check the warranty terms or consult Synology support for clarification.

Q: Can I use this solution for other Synology models as well? A: While this solution has been specifically tested and proven to work on the Synology Rock Station RS815 Plus, it is possible that it may be applicable to other models with similar issues. However, it is recommended to consult the Synology support website or seek professional advice for specific models.

Q: Is it necessary to follow the steps exactly as described in the article? A: It is advisable to follow the steps precisely to ensure the best results and avoid any potential damage to the NAS server or its components. However, individual circumstances may vary, so adapt the steps accordingly if needed.

Most people like

Are you spending too much time looking for ai tools?
App rating
4.9
AI Tools
100k+
Trusted Users
5000+
WHY YOU SHOULD CHOOSE TOOLIFY

TOOLIFY is the best ai tool source.

Browse More Content